Colored Dissolved Organic Matter Analyzer Sensor [wptab name=’Fitur’] All-in-One Compact Housing, Built-in Transmitter and Sensors Robust IP68 Water Submersible Protection, Directly Installed in the Field, No Cabinet Required Plug & Play, On-line Realtime Measurement Ultra Low Power Consumption, Ideal for Outdoor Applications 1500 N Tensile Strength Kevlar Reinforced Cable Surge Protection for Power and RS485 Communication RS485 Digital Communication, Minimize Cabling and Engineering Cost Standard Modbus RTU Protocol, Direct Connected with PLC, HMI Sapphire Glass Windows to Prevent Scratch Innovative Nano Coating to Remain Window Clean Auto Cleaning Wiper, Less Maintenance Onboard Memory Allowing Users Easily Calibrate and Configure Sensor at Lab and Distribute to Various Fields and Sites AQCFG Software Tool for Data Monitoring, Calibration, Configuration and Diagnosis IECEx/ATEX Ex ia IIB T5 Ga Explosive Proof Certification [/wptab] [wptab name=’Spesifikasi’] GENERAL Output Signal RS485 (Modbus RTU protocol), 19,200 bps, 8 data bits, no parity, 1 stop bit; 4~20 mA (optional) Data Resolution 16 bits (0.001% FS) Surge Protection 1,500 VDC Power 5~12 VDC, 118 mA Protection Polarity, Overload, Short circuit Safety CE, FCC UNIT Colored Dissolved Organic Matter Analyzer Measurement Method Fluorescence Measurement Range 0~3,000 ppb (μg/L) Accuracy Linearity R² > 0.999 for serial dilution of Quinine Sulfate solution equivalents in 0.1 N H2SO4 at concentrations ranging from 0~300 μg QL L-1 Resolution 0.01 μg/L Repeatability ±1% FS Light source LED 355 nm Operation pressure Max. 10 Kgf/cm² Operating temperature 0~50 °C Process flow rate 0.1~10 m/s Response time 3 secs Calibration Interval Typical 24 months Protection IP68 Connection M16X1.5 plug fixed cable, M12 connector, 5 pin Cable Kevlar reinforced PUR cable, 1500N tensile strength Housing SS316L; Titanium Dimension ø 22Χ130 mm (no wiper) ; ø 39Χ186 mm (with wiper) Weight analyzer: approx. 500 g (SS316L) ; 400 g (Titanium) ; Cable: 80 g/m [/wptab] [end_wptabset] Harga: hubungi kontak kami Author Akhmad Hidayat Publish Date May 23, 2025 Category Online Water Quality AnalyzersProduk Read Time 1 minute Artikel Terkait Perawatan Isokinetic Sampling & Gas Analyzer agar Hasil Uji Emisi Akurat Prediksi Banjir Real-Time: Keunggulan AWLR Berbasis Radar Hygiene Monitoring untuk Industri Food & Hotel: Cara Menjaga Standar Kebersihan dan K3 Urgensi IPAL Komunal untuk Sanitasi Lingkungan Masyarakat Monitoring Emisi Kendaraan Logistik dengan CEMS Transportasi di Hari Angkutan Nasional Author Akhmad Hidayat Publish Date May 23, 2025 Category Online Water Quality AnalyzersProduk Read Time 1 minute Colored Dissolved Organic Matter Analyzer Sensor [wptab name=’Fitur’] All-in-One Compact Housing, Built-in Transmitter and Sensors Robust IP68 Water Submersible Protection, Directly Installed in the Field, No Cabinet Required Plug & Play, On-line Realtime Measurement Ultra Low Power Consumption, Ideal for Outdoor Applications 1500 N Tensile Strength Kevlar Reinforced Cable Surge Protection for Power and RS485 Communication RS485 Digital Communication, Minimize Cabling and Engineering Cost Standard Modbus RTU Protocol, Direct Connected with PLC, HMI Sapphire Glass Windows to Prevent Scratch Innovative Nano Coating to Remain Window Clean Auto Cleaning Wiper, Less Maintenance Onboard Memory Allowing Users Easily Calibrate and Configure Sensor at Lab and Distribute to Various Fields and Sites AQCFG Software Tool for Data Monitoring, Calibration, Configuration and Diagnosis IECEx/ATEX Ex ia IIB T5 Ga Explosive Proof Certification [/wptab] [wptab name=’Spesifikasi’] GENERAL Output Signal RS485 (Modbus RTU protocol), 19,200 bps, 8 data bits, no parity, 1 stop bit; 4~20 mA (optional) Data Resolution 16 bits (0.001% FS) Surge Protection 1,500 VDC Power 5~12 VDC, 118 mA Protection Polarity, Overload, Short circuit Safety CE, FCC UNIT Colored Dissolved Organic Matter Analyzer Measurement Method Fluorescence Measurement Range 0~3,000 ppb (μg/L) Accuracy Linearity R² > 0.999 for serial dilution of Quinine Sulfate solution equivalents in 0.1 N H2SO4 at concentrations ranging from 0~300 μg QL L-1 Resolution 0.01 μg/L Repeatability ±1% FS Light source LED 355 nm Operation pressure Max. 10 Kgf/cm² Operating temperature 0~50 °C Process flow rate 0.1~10 m/s Response time 3 secs Calibration Interval Typical 24 months Protection IP68 Connection M16X1.5 plug fixed cable, M12 connector, 5 pin Cable Kevlar reinforced PUR cable, 1500N tensile strength Housing SS316L; Titanium Dimension ø 22Χ130 mm (no wiper) ; ø 39Χ186 mm (with wiper) Weight analyzer: approx. 500 g (SS316L) ; 400 g (Titanium) ; Cable: 80 g/m [/wptab] [end_wptabset] Harga: hubungi kontak kami Artikel Terkait Perawatan Isokinetic Sampling & Gas Analyzer agar Hasil Uji Emisi Akurat Prediksi Banjir Real-Time: Keunggulan AWLR Berbasis Radar Hygiene Monitoring untuk Industri Food & Hotel: Cara Menjaga Standar Kebersihan dan K3 Urgensi IPAL Komunal untuk Sanitasi Lingkungan Masyarakat Monitoring Emisi Kendaraan Logistik dengan CEMS Transportasi di Hari Angkutan Nasional