Blue Green Algae Analyzer Blue Green Algae Analyzer Features: Solution Without Cabinet , robust IP 68 Water Submersible Enclosure On-line Realtime Measurement 1 second Ideal for Outdoor Applications, 0.02 W Ultra Low Power Consumption Temperature Compensation Drift Free , High Reliability RS 485 Communication and lightening and Surge Protection for Power Engineering Cost and 1.2 Km RS 485 Digital Communication Data Monitoring and Software Configuration Calibration Configure sensor at lab and distribute to various fields sites and on board memory allowing users to easily calibrate Direct Connected with PLC, Standard Modbus RTU Protocol, Eliminate I/O Module Cost, HMI Specification: Parameter 36-1: Phycocyanin (PC) 36-2: Phycoerythrin (PE) Measurement range 36-1: 0 – 4,500 ppb (μg/L), 0~150,000 cells/ml 36-2: 0 – 4,500 ppb (μg/L), 0~450,000 cells/ml Accuracy ± 3% FS Resolution 0.01 ppb Repeatability ± 1% FS Light source 36-1: LED 590 nm 36-2: LED 525 nm Operation pressure Max. 5 Kg f/cm2 Operating Temperature 0 – 85 °C Process flow rate Min. 0.1 m/sec Response time 3 sec Protection IP 68 Temperature sensor Pt 100 Temperature measurement range 0 – 85°C Temperature accuracy ± 0.5 °C ; ± 0.1 °C (Optional) Housing SS 316 L ; Titanium Dimension 35 Χ 215 mm Weight Analyzer: approx. 500 g; Cable: 80 g/m Author Akhmad Hidayat Publish Date May 23, 2025 Category Online Water Quality Analyzers Read Time 1 minute Artikel Terkait Perawatan Isokinetic Sampling & Gas Analyzer agar Hasil Uji Emisi Akurat Prediksi Banjir Real-Time: Keunggulan AWLR Berbasis Radar Hygiene Monitoring untuk Industri Food & Hotel: Cara Menjaga Standar Kebersihan dan K3 Urgensi IPAL Komunal untuk Sanitasi Lingkungan Masyarakat Monitoring Emisi Kendaraan Logistik dengan CEMS Transportasi di Hari Angkutan Nasional Author Akhmad Hidayat Publish Date May 23, 2025 Category Online Water Quality Analyzers Read Time 1 minute Blue Green Algae Analyzer Blue Green Algae Analyzer Features: Solution Without Cabinet , robust IP 68 Water Submersible Enclosure On-line Realtime Measurement 1 second Ideal for Outdoor Applications, 0.02 W Ultra Low Power Consumption Temperature Compensation Drift Free , High Reliability RS 485 Communication and lightening and Surge Protection for Power Engineering Cost and 1.2 Km RS 485 Digital Communication Data Monitoring and Software Configuration Calibration Configure sensor at lab and distribute to various fields sites and on board memory allowing users to easily calibrate Direct Connected with PLC, Standard Modbus RTU Protocol, Eliminate I/O Module Cost, HMI Specification: Parameter 36-1: Phycocyanin (PC) 36-2: Phycoerythrin (PE) Measurement range 36-1: 0 – 4,500 ppb (μg/L), 0~150,000 cells/ml 36-2: 0 – 4,500 ppb (μg/L), 0~450,000 cells/ml Accuracy ± 3% FS Resolution 0.01 ppb Repeatability ± 1% FS Light source 36-1: LED 590 nm 36-2: LED 525 nm Operation pressure Max. 5 Kg f/cm2 Operating Temperature 0 – 85 °C Process flow rate Min. 0.1 m/sec Response time 3 sec Protection IP 68 Temperature sensor Pt 100 Temperature measurement range 0 – 85°C Temperature accuracy ± 0.5 °C ; ± 0.1 °C (Optional) Housing SS 316 L ; Titanium Dimension 35 Χ 215 mm Weight Analyzer: approx. 500 g; Cable: 80 g/m Artikel Terkait Perawatan Isokinetic Sampling & Gas Analyzer agar Hasil Uji Emisi Akurat Prediksi Banjir Real-Time: Keunggulan AWLR Berbasis Radar Hygiene Monitoring untuk Industri Food & Hotel: Cara Menjaga Standar Kebersihan dan K3 Urgensi IPAL Komunal untuk Sanitasi Lingkungan Masyarakat Monitoring Emisi Kendaraan Logistik dengan CEMS Transportasi di Hari Angkutan Nasional